Custom Sauna (Outdoors)
See below for an example of an outside sauna Quote:
Profiled Spruce boards (cladding) for walls and ceiling
- Spruce imported from Austria with dimensions 12.5 x 96 x 2000mm,
- Cladding is quality controlled by the Federation of European Planing Mills (VEH).
- no toxic fumes are released, even at very high temperatures in excess of 90 degrees Celsius.
Dual Level Obeche benches
- Floating (open fronts) to ensure relaxing reclining, easy cleaning under benches and maximum air circulation.
- Each bench +- 550mm wide with gaps between each slat.
- one high level bench on one side
- one low bench on the other side
Non-slip Duckboards of Obeche
- removable for easy cleaning
- duckboards in front of benches only
- All Obeche benches and duckboards are hand-selected and Arrised with dimensions 69mm (wide) x 22mm (thick), screwed and glued from underneath.
Fully insulated walls and ceiling with 40mm thick non-rotting, non-allergenic, non-irritant and non-separating polyester fiber.
Blind fixings on walls, ceilings, and benches to ensure no exposed nails or screws, which could lead to "hot-spots".
Dimmable mood-light in corner 220V / 50W.
Toughened Frameless Glass Door (6mm thick),
- +-720mm x 2000mm, opening outwards.
- Clear or bronzed with beveled edges.
- Heavy hinges, with wooden handle.
Hot Rock Stainless Steel Sauna Heater:
- 9 Kw (3x3kw) 3phase, OR 5 kw (3kw + 2Kw) 1phase
- Heater dimensions 410mm (Width) x 250mm (Depth) x 570mm (Height)
- Wall mounted
- Obeche heater guard to avoid accidental contact
- Double skinned (both skins stainless steel) to avoid heat radiating outwards
- Easy Access Digital Control with Countdown Timer and Temperature display (mounted outside of the sauna)
Thermostatically controlled temperature settings- Sauna rocks
Accessories include
- Combination wooden Hygrometer / Thermometer
- Wooden Sauna Bucket
- 1 year guarantee
Project Management; Installation Schedule; and extra billing for non-compliance:
- 1st Site Meeting (+- 2hrs included in price):
When? - On receipt of Deposit, and before final construction of 4 walled sauna structure and before sauna tiling on floor.
With Whom? - Scheduled with Project Manager, Electrician, Builder and Architect/Owner. All custom fittings will be supplied and instructions provided for pre-requisite sauna installation requirements; as well as sauna heater location, conduit for electricity, low voltage controls, temperature probe, bench and door positions finalized.
- Subsequent Site visits scheduled to build sauna +- 7 working days:
When? - after four walled structure is complete, (with roof for exterior structure).
Project Manager must VISUALLY CONFIRM that the following is in place:
- tiled floor with optional fall for drainage.
- electricity supply from main DB Board with appropriately rated wiring.
- If 9kw 3 phase = WIRE 2.5mm thick Four Core & Earth; CIRCUIT BREAKER Three Pole 20 amp OR
- If 5kw 1 phase = WIRE 2.5mm Live Neutral and Earth; CIRCUIT BREAKER Single Pole 20 amp
- splash proof isolator switch located in as close a proximity to the anticipated location of the sauna heaters final position as possible
- 32mm Conduit (with pull wire) for low voltage control wires to be pulled from sauna control area to sauna heater location.
- 20mm Conduit (with pull wire) for temperature probe to be installed in sauna roof or wall.
- Light switch with dimmer installed with wiring in conduit leading to sauna roof
With Whom? Scheduled with Project Manager OR owner, so that the sauna woodwork can commence.
- If further site visits are required, because of non-compliance with above specifications after being informed that they are complete, then any additional site visits will be BILLED SEPARATELY by the hour, over and above the contract price.